CD450-50J SINGLE CIRCUIT MACHINE

CD450-50J SINGLE CIRCUIT MACHINE

The REO BM175-10PT Sequential Blasting Machine is a modern easy-to-use programmable timing machine meeting the special requirements of bench blasting operations where precise millisecond/microsecond accuracy is critical.

Programmable timing permits the blaster to take full advantage of the greater accuracies offered by the new electric detonators to achieve better fragmentation and to control ground vibration. The REO Sequential Blasting Machine allows the blaster to continue full production blasting which otherwise would be drastically curtailed if a single circuit machine were employed.

This blasting machine is of solid-state capacitor-discharge design with 10 output (cap) circuits.

The REO PT Blasting Machine fires the cap circuits one after the other sequentially at pre-selected time intervals for 1 to 999 milliseconds in 1 millisecond increments. For special requirements, timing selection increments of 100 microseconds to 10 milliseconds is offered.

The BM175 Blasting Machine is a 450 volt output model. This model has a cable receptacle on the top panel and requires an EC15 series Extension Cable and TB15 Terminal Board to connect to the detonator lead lines.

The timing intervals between circuits are selected and set independently on each of nine switches, and the selected timing may be DIFFERENT between each circuit.

Detalles Adicionales

  • FEATURES

    • Solid-state circuitry assures excellent reliability and service life
    • Safety Interlock.
    • Sturdy construction for extended service life.
    • Rugged water and environmentally sealed to operate in most weather.
    • Heavy-duty, long life, ALKALINE batteries provide efficient and dependable power.
    • Fast battery change, temperature compensated circuits facilitate cold weather operation.

  • OPERATION

    • This equipment must be operated in accordance with US Federal health and safety standards, state laws, rules and other applicable statutory provisions.
    • Devices such as the REO Blasting Machine Energy Testers must be used to determine the energy output of each circuit prior to each blast.
    • After the lead lines have been connected to the blasting machine, depress the CHARGE switch and hold it down.
    • When the READY TO FIRE indicator lights, depress the FIRE switch while continuing to depress the CHARGE switch. Unless the CHARGE and FIRE switches are operated together, the machine will not fire.

  • BATTERY LIFE:

    • UP TO 475 Charges
    • A lighted READY TO FIRE indicator confirms that the battery power was sufficient to charge the capacitors to the design voltage and the safety circuit is released.
    • After months of firing cycles, a longer charge time will be required. However, regardless of battery condition, the full design voltage is present and the unit's safety circuits are released if the READY TO FIRE indicator is illuminated

Model No.:

CD450-50J

Energy Output:

450 Volts / 50 Joules

Capacity:

222 Ohms (105 Electric Blasting Caps)

Parallel Series:

8 Series of 63 2-ohm

Electric Blasting Caps

Weight:

5.2 lbs.

Size:

10.3” x 7.3” x 4.1”

Power Source:

Eight 1.5 Volt “AA” Cell Batteries